This article explains which grading panels work with each supported application and how to connect your panel to your cloud workstation.
Before you begin
Before you connect your grading panel, complete the following:
- Share your panel model with Production Technology (post-support@amazonstudios.com) before your scheduled set-up session. Some panels need configuration on the cloud workstation in advance.
- Update HP Anyware on your local computer to the latest version.
- Update your panel's firmware to the latest version available from the manufacturer.
Which panel works with which app?
| Panel | Works with | How it connects |
|---|---|---|
| Tangent | DaVinci Resolve, Colorfront OSD (already configured for dailies) | Over USB, through HP Anyware |
| DaVinci panels (Micro, Mini, Advanced) | DaVinci Resolve | Over your network, with a small script on your computer |
| Blackboard | Baselight | Tell us before set-up |
When should I contact support before I start?
Contact Production Technology (post-support@amazonstudios.com) before you begin if:
- You're using a FilmLight Blackboard panel. Support for Blackboard in the cloud environment is currently being confirmed.
- Your show uses Amazon DCV. This article covers HP Anyware connections only. Support can confirm the correct panel set-up for DCV workstations.
How do I connect my Tangent panel?
- Turn on USB auto-forwarding. In the HP Anyware client, click the Settings (gear) icon, select USB Devices, and turn on USB auto-forwarding.
- Connect the Tangent devices. After your session connects, go to Connection › USB Devices and select Show HID Devices. Click Connect next to each Tangent device. Each device should show a status of Accepted.
- Set up the panel in DaVinci Resolve. In Resolve, go to Preferences › Control Panels, select your Tangent device, and click Save. Restart Resolve to apply the change.
- A device shows as unauthorised? Tell us: it's a setting on our side.
How do I connect my DaVinci panel?
DaVinci Resolve panels connect to the cloud workstation over the network rather than through USB forwarding. A remote panel script runs on your local computer and relays panel input to Resolve in the cloud.
Prerequisites
- DaVinci Resolve is installed on your local computer, at the same version as the cloud workstation.
- Your IT team has opened inbound port 20323 on your network and forwarded it to your local computer.
- You have your network's public IP address. Your IT team can provide it.
Steps
- Test the panel locally. Open DaVinci Resolve on your local computer and confirm the panel works. Then quit local Resolve completely.
- Start the remote panel script. Run the script on your local computer and wait for this message: "Resolve communication is open and waiting...". Leave the script running for the whole session.
- Connect to your cloud workstation. On a Mac, open the HP Anyware client with USB disabled, so the script keeps control of the panel.
- Configure Resolve in the cloud. In Resolve on the cloud workstation, go to Preferences › Control Panels, select your panel model, and open Advanced Settings. Add your public IP address and the port. Click Save, then restart Resolve.
Important: always start the remote panel script before you open Resolve on the cloud workstation. If Resolve opens first, quit it, confirm the script is running, then start Resolve.
Still not working? See the next question.
My DaVinci panel won't connect or keeps dropping. What do I check?
Connection recommendations
- Use Ethernet when your panel supports it. An Ethernet connection is more stable than USB for remote panel sessions.
- If you use USB: start the remote panel script and wait for it to confirm the connection. Then unplug the panel's USB cable and plug it back in.
Checks
- No activity in the script window? The script isn't running, or it's the wrong one for your panel and computer.
- Panel unresponsive? Check the public IP address in Resolve and your IT team's firewall rule.
If the issue continues, contact Production Technology (post-support@amazonstudios.com) with your panel model, your operating system, and a screenshot of the script window.
What does our facility IT need to open?
- DaVinci panels: inbound port 20323, forwarded to the computer running the script. Check DPI or IPS isn't dropping it.
- Blackboard with Baselight: inbound TCP 5950.
- FilmLight Remote picture (Baselight, Daylight): inbound UDP 1997 (see FilmLight Remote: Watch Your Baselight or Daylight Session).
Still stuck? We've got you
Your Amazon Post Exec or vendor manager is often the fastest way out: they know your show.
| If it's… | Contact | When |
|---|---|---|
| Signing in: password, Okta, MFA, a new phone, locked out, or access to Box, Flow Capture or Aspera on Cloud | TechOps · support@amazonstudios.com | 24/7 |
| Anything else in the cloud: workstations, Avid, Resolve, Nexis, transfers, storage, set-up | Production Technology · post-support@amazonstudios.com | Mon-Fri · 6 AM-2 AM UK (10 PM-6 PM Pacific) |
| An outage: your Lot One production is down | Emergency contact form → · choose Cloud Production Technology Support, set Request Type to Outage and Severity to 2 | 24/7 |
Get help faster: send your name and show, the machine name, the exact error (a screenshot is perfect) and what you've already tried. One email per problem.